Fenice – Gruppo EDF

Main navigation Go to content [C]



Plant's data

 
Number of lines2Rotary furnace (for industrial waste)Grid furnace (for urban waste)
Total load of waste t/h 5 4,3
Total authorised load of waste t/y 35.000 30.000
Total authorised nominal heating power MW 31,4 18,7
Annual production of heat MWht 30.000
Steam pressure Bar 35
Steam temperature 350
Nominal electric power MWe 7.3
Annual production of electricity MWhe 30.000 (*)
Hours of operation/year h 7.000 7.000
 

EMISSIONS OF THE MELFI PLANT

 
ParameterUnit/measurementLegal limitAnnual average (*)
Chloridric acid mg/Nm3 10 0.8
Carbon monoxide mg/Nm3 50 1,8
Nitrogen oxides (NOX) mg/Nm3 200 113
Sulphur oxides mg/Nm3 50 7
Organic carbon, Tot. mg/Nm3 10 0.9
Powders mg/Nm3 10 2.1
Mercury mg/Nm3 0,05 0.01
HF mg/Nm3 2 0.1
Cd+Tl mg/Nm3 0.05 0.001
Sb+As+Pb+Cr+Co+Cu+Mn+Ni+V mg/Nm3 0.5 0.04
PCDD+PCD ng/Nm3 0.1 0.001
IPA mg/ Nm3 0.01 0.00001
 

(*) AVERAGE DATA 2010